Coriolis type flow meter provider right now? Install the total steam flow meter before the pressure reducing valve. Since the above-mentioned steam has not been decompressed, there is no phase change problem, so install the flowmeter before the pressure reducing valve, and use the saturated steam compensation method to ensure the measurement Accuracy. If the flowmeter can only be installed behind the pressure reducing valve, a pressure transmitter can be added for temperature and pressure compensation. If the stability of the pressure reducing valve is good, the upstream pressure value of the flowmeter can be set as a constant value in the display instrument for temperature and pressure compensation.

Vortex flow meter is the fluid Reynolds number is within a certain range, and its output is only proportional to the volume flow. The output of vortex flowmeter has frequency signal and analog signal, and the analog output is obtained by f/ conversion on the basis of frequency output. This conversion loses about 0.1% accuracy. Therefore, when it is used to measure the steam flow, users prefer to use the frequency output. There are several other reasons why frequency output vortex flowmeters are more popular with users such as thermal companies. Discover more information on https://www.bjssae.com/v-shape-coriolis-mass-flow-meter.html.

China Capital technology group invested in the SINOPEC automation instrument department of Beijing institute of chemical industry. Beijing shouke shí huà automatic equipment Co., LTD (Beijing Sincerity’s predecessor) was officially established. “Shí huà” is the Chinese words from SINOPEC. Sincerity officially switched from a national company to joint-stock company. Beijing shouke shí Huá ( which is Beijing Sincerity Automatic Equipment Co., Ltd now ) was officially established. The Chinese pronunciation of “shí Huá “ and “ shí huà” are very close to each other. The 1st generation coriolis mass flow meters were officially launched. The coriolis mass flow meters are with all discrete components, little chips and LED digital display.

Second, the gas turbine flow meter equipment has strong functions, low power consumption and superior performance. When it is sold in the industry, it is found that the functional advantages of this kind of flowmeter will be more perfect. In many gas distribution stations or gas When promoting in the station, I found that the advantages will be more diversified, and there are more and more advantages. Third, the configuration of the natural gas turbine flow meter instrument is more perfect, and it will be more and more widely used. As long as you take a fancy to the above clarity, it will be more convenient in the process of normal use. After this is used in many gas distribution stations, it is found that the measurement accuracy is higher.

Turbine Flow Meter has the characteristics of high accuracy, good repeatability, convenient installation and maintenance, and simple structure. Liquid flows through the turbine casing, causing the internal rotor to rotate. When the rotor rotates, an electrical signal is generated in the pickup coil. This signal is converted to engineering units (liters, cubic meters, gallons, etc.) on the applicable local display. Optional accessory modules can be used to export signals to other devices. Make sure the vortex flow meter model meets your specific needs. For your future reference, if this information becomes unreadable on the turbine, it may be useful to record it on the nameplate of the manual. See the nameplate for your custom product specifications. Read more details at https://www.bjssae.com/.

Sincerity, excellence in coriolis flow meter production with 33 years experience, Since 1987.Through continuous research, development and transformation, we have become the leader of the Coriolis Mass Flow Meters industries in China.Our products including coriolis mass flow meter,thermal mass flow meter,fork density meter and etc.We have 100+ workers and 5000+ factory,our customers from all over the world. We support OEM coriolis mass flow meter name plates.