Quality pharma clean room manufacturer factory: Clean room equipment includes air purification equipment and air ventilation equipment. During the construction process, it is necessary to select the appropriate air filtration equipment according to specific practical needs. In general, the selection of air purification equipment will use coupled filtration technology to achieve the purpose of eliminating dust in the air, that is, through multiple layers of different filtration forms, to eliminate foreign particles and harmful substances in the air. Read even more info on clean room in pharmaceutical industry.

The laboratory with multiple combinations can adopt single channel design, double channel design, and standard unit combination design. The structure of the laboratory should have applicability, versatility and flexibility to meet the needs of the subsequent development, renovation and expansion. Experimental rooms involving radioactivity, pollution and personal harm and other special requirements, the building layout, maintenance structure, decoration should meet the corresponding professional and technical requirements. The laboratory should be cleaned and disinfected regularly; ground, wall and ceiling shall be integral waterproof and dust-proof construction. The interior should reduce the protruding building fittings and open pipes; Between the wall and wall, the wall and ground, the wall and ceiling should be made of a radius of not less than 0.05m semi-rounded corner.

Because of the different standards and machine styles, the die of tablet press can be divided into single tablet press die and rotary tablet press die. According to different specifications, diameter and tablet shape, the stamping dies of single stamping tablet machine and rotary tablet press can be divided into circular stamping dies and special-shaped stamping dies (triangle, oval, key type, plum blossom, rectangle, etc.), which can be customized according to your needs.

Why is Proper Humidity Important in Clean Rooms? Maintaining proper humidity levels in clean rooms is crucial for several reasons: Prevention of Condensation: High humidity levels can cause condensation on surfaces, leading to potential damage to sensitive equipment or materials. Lower humidity levels prevent this issue by reducing water vapor in the air. Mold Growth: High relative humidity levels promote the growth of mold and mildew, which can negatively impact the cleanliness and functionality of clean rooms. Ensuring proper humidity levels helps prevent mold growth and associated health hazards.

The plane and space design of the clean laboratory will arrange the clean experimental area and personnel purification, equipment and material purification and other auxiliary rooms in different areas. At the same time, the comprehensive coordination effects of various technical facilities, such as experimental operation, process equipment installation and maintenance, air distribution type, pipeline layout and purified air conditioning system, are considered.

For the unidirectional flow (laminar flow) clean room, the air supply volume is determined by the product of the average wind speed of the room section and the cross-sectional area, in which the measured section of the vertical unidirectional flow (laminar flow) clean room is the horizontal section 0.8m away from the ground; The horizontal unidirectional flow (laminar flow) clean room takes a vertical section 0.5m away from the air supply surface. The spacing of measuring points on the section shall not be greater than 2m, and the number of measuring points shall not be less than 10, which shall be evenly arranged. Hot bulb anemometer for instrument.

Premium pill stamp press manufacturer: Today (Suzhou Pharma Machinery Co., Ltd.) will introduce to you, clean room airflow and influencing factors. There are many factors affecting the airflow in the clean room, such as process equipment, personnel, clean room assembly materials, lighting fixtures, etc. At the same time, the distribution point of airflow above the production equipment should also be considered.

The frame of the clean shed can be generally divided into three types: stainless steel square pass, varnished iron square pass and industrial aluminum profiles. The top and the top can be made of stainless steel steel plate, lacquered cold plastic steel plate, anti-static mesh curtain and acrylic plexiglass and other materials. Anti-static mesh curtains or plexiglass are generally used around, and FFU clean air supply units are used in the air supply unit.

The above introduction is related to the introduction of clean room and testing purpose.If you have different opinions or suggestions, you can always contact us.As long as you want the clean room project, Suzhou Pharma Machinery Co., Ltd. will realize it for you.Choose a reliable engineering company, Suzhou Pharma Machinery Co., Ltd., will be responsible for your project to the end, and the reputation is guaranteed.Our company has completed 500+ clean room projects all over the world. Many new and old customers like to buy the products they want in our company. The price is reasonable, the integrity is guaranteed, and the after-sales service is good.If you have related (clean room) projects recently, you can contact us at any time. Find extra details at https://www.sz-pharma.com/.