Top gmp panel manufacturer and supplier: The material of the equipment is safe, stable, heat-resistant, and corrosion-resistant. Completely enclosed during production, it will not cause pollution to the outside environment, nor will it be contaminated by the outside environment. The equipment should be easy to clean and preferably have a self-cleaning function. Pharmaceutical equipment has an automatic control system that can systematically control, count, and reduce labor costs. Some drugs have special properties, so it is best for pharmaceutical equipment to have dust-proof, waterproof, and explosion-proof functions. For safety reasons, there should be a one click pause automatic protection equipment. See even more details at pill stamp press.
Tablet press is mainly used for tablet technology research in pharmaceutical industry. The tablet pressing machine presses powder or granular raw materials into tablets. Its scope of application: Traditional Chinese medicine, western medicine, health products, food, chemical industry, electronics and other industries. The prefabricated container house is a new concept of environmentally friendly and economical house with light steel H-shaped steel and channel steel as the framework, sandwich panel as the wallboard material, space combination with standard modulus series, and bolted or welded components.
The filling speed of the capsule filling machine is fast, and the size difference of the capsule filling machine is small. It integrates the powder capsule shell finishing, capsule cap finishing and capsule package, which is compact and convenient. In addition, the capsule filling machine has many advantages, such as fast arrangement speed, high efficiency, simple operation, convenient maintenance and low power consumption. It is the preferred capsule filling (filling) machine for pharmaceutical factories, health product factories, hospital preparation rooms, etc
As industries and research labs continue to embrace clean rooms as essential components of their operations, it’s crucial for professionals to understand the ideal cleanroom humidity levels within these controlled environments. Clean rooms, also known as sterile rooms or anti-static rooms, are designed to minimize contamination from dust, debris, and other environmental factors. Maintaining optimal humidity levels is an integral part of ensuring the cleanliness and functionality of clean rooms. In this blog post, we’ll discuss the normal humidity range for clean rooms and how to maintain them effectively.
Usually, the movement or activity of personnel should be reduced as much as possible in the laboratory, and the door of the clean room should be closed or automatic door closers should be installed to keep it closed. Stop use immediately when the cleanliness does not meet the requirements: When the cleanliness does not meet the requirements, it should be stopped immediately, find the cause, thoroughly clean, must be verified by the cleanliness and meet the requirements, and then use again, and record the situation in the aseptic room use register, regular archival storage. Guidance and supervision of incoming foreign personnel or maintenance personnel: non-microbial room inspection personnel shall not enter the clean room (aseptic room), and foreign personnel or maintenance personnel who must enter shall be guided and supervised.
The plane and space design of the clean laboratory will arrange the clean experimental area and personnel purification, equipment and material purification and other auxiliary rooms in different areas. At the same time, the comprehensive coordination effects of various technical facilities, such as experimental operation, process equipment installation and maintenance, air distribution type, pipeline layout and purified air conditioning system, are considered.
For the tuyere equipped with filter, the auxiliary air duct can be selected according to the tuyere form, that is, the straight pipe section with the same section as the tuyere and the length equal to twice the side length of the tuyere is made of hard plate, which is connected to the outside of the filter tuyere. The measuring points are evenly arranged on the outlet plane of the auxiliary air duct according to the minimum number of measuring points, and the wind speed of each point is measured with a hot ball anemometer. The air volume is determined by multiplying the average wind speed at the section of the air outlet by the net section area of the air outlet.
Quality pharma clean room company supplier: Generally, the air flow distribution point on the surface of the operating table or production equipment should be located at 2/3 of the distance between the clean room space and the partition wall, so that when the operator is working, the air flow can flow from the inside of the process area to the operation area, and the The dust is taken away; if the distribution point is arranged in front of the process area, it will become an improper airflow distribution. At this time, most of the air flow will flow to the process area, and the dust caused by the operator’s operation will be brought to the back of the equipment. As a result, the platform will be polluted, and the yield rate is bound to decrease.
Clean shed, also known as clean work shed (dust-free shed, purification shed, operating table, etc.), is a small space surrounded by anti-static mesh curtains or plexiglass in the clean room, and HEPA and FFU air supply units are used above. It is composed of a space with a higher purification level than the clean room, and the clean room can be equipped with purification equipment such as air shower room and transfer window.
Many single-flow type clean rooms are designed as vertical laminar flow, so the uniformity of wind speed is very important. Only uniform vertical laminar flow can effectively eliminate particulate pollution. For non-single-flow type clean rooms, since the concept of particle control is dilution, not immediate elimination, generally speaking, the air exchange rate is far more important than the wind speed, so it is only necessary to measure the air volume. Find additional info on https://www.sz-pharma.com/.