High quality transformer core cutting machine supplier factory: When these harmonic currents flow through a transformer, they can cause increased core losses due to hysteresis and eddy currents. Hysteresis loss is related to the magnetization and demagnetization of the transformer’s core material in response to the alternating current. Eddy current loss occurs when induced currents circulate within the core material, creating local magnetic fields that oppose the main field. Both these losses increase with the frequency of the current. Thus, higher frequency harmonic currents can lead to considerably higher core losses, reducing the transformer’s efficiency and causing it to overheat, which can shorten its lifespan. Find even more details on transformer core cutting line.
A China slitting line produces longitudinal cuts in a master coil of steel to predetermined narrower widths. These smaller coils are then sent to downstream operations such as metal stampers, tube producers or roll forming houses that will use the material in their final product. Customized slitting line machine equipment mainly includes the following: Loading trolley, double support uncoiler, feeding device, traction leveling machine, trimming shearing machine, deviation correction feeding device, longitudinal shear line, waste edge winder, feed rack, pre separation device, tensioner, feeding roller, winding shearing machine, steering drum, rear axle, discharge trolley, winding auxiliary support, hydraulic system and electrical system, etc.
Box transformer (usually referred to as “box transformer”) is a compact complete set of power distribution equipment composed of high-voltage power equipment, power transformer, low-voltage electrical equipment and auxiliary equipment. Canwin, a professional box transformer manufacturer & supplier, which focuses on the substation type transformer and traditional box type transformer design in the box shell, A box type transformer is an electronic device that transforms power into alternating current for the purpose of transferring power from one point to another.With small volume, light weight, low noise, low loss, high reliability. Transformer box is widely used in residential areas, commercial centers, light stations, airports, factories and mines, enterprises, hospitals, schools and other places.
Adopt energy-saving measures: During the operation of the transformer, energy-saving measures can be adopted, such as adopting a high-efficiency cooling system, reducing the load rate of the transformer, optimizing the operation scheduling of the transformer, etc., to reduce energy loss and improve efficiency. Regular maintenance and overhaul: Regular maintenance and overhaul of transformers can maintain the normal operation and stability of transformers, thereby reducing energy loss and improving performance. Choose the appropriate transformer connection method: Different connection methods of the transformer will also affect the performance of the transformer. When choosing a transformer connection method, the optimal connection method can be selected according to actual needs and load characteristics to improve efficiency. To sum up, improving transformer efficiency can be achieved by optimizing design, selecting high-quality materials, adopting energy-saving measures, regular maintenance and overhaul, and selecting appropriate connection methods. In practical applications, various factors need to be considered comprehensively to select the most suitable method for improving performance.
Laser welding machine is an efficient and precise welding method using high energy density laser beam as a heat source. Laser welding is one of the important applications of laser material processing technology. It mainly used for welding thin wall material and low speed in the 1970 s. The welding process is thermal conduction, i.e. the laser radiation heating surface, the surface heat to the internal diffusion through heat conduction, by controlling the width of laser pulse, energy, peak power and repeating frequency, parameters such as melting of components, to form specific molten pool. Because of its unique advantages, it has been successfully used in precision welding of micro and small parts.As one of the best laser welding machine manufacturers in China, Canwin specialized in handheld laser welding machine and wholesale fiber laser welding machine making for over 20 years.
CANWIN is not just a length lines company, but also electrical equipment manufacturer. It is the legend of people who have forged their lives with faith and action. CANWIN electrical machinery equipment manufacturing deploys an innovation chain through the industrial chain.Equipment sales can provide integrated solutions; can provide OEM/ODM services to global transformer manufacturers; can provide raw material supply to transformer manufacturers. In the form of cooperation and mutual benefit, set up the transformer manufacturing center and core processing base in the Middle East, India. Dubai. Vietnam. Thailand. etc.
As a result of mutual inductance, a transformer produces a transformed voltage or current when the magnetic flux produced by one winding (primary winding) links with another winding (secondary winding). There is a magnetic coupling between these two windings, and they are electrically isolated. In addition, magnetic reluctance is also known as opposition to magnetic flux flow. If, for example, the magnetic flux produced by a primary winding passes through air or any nonferrous material in order to reach a secondary winding in a transformer, it would result in a reduction in magnetic flux. Due to the high reluctance of air or nonferrous materials, it will reduce magnetic flux. Find additional info on https://www.canwindg.com/
With the development of the times, people’s demand for power supply and the reliability of power supply are increasingly high, so the smart grid has emerged accordingly.In the power system, the core and hub of the substation is the transformer.The function of the transformer is mainly to distribute and convert electric energy. The normal operation of the transformer directly affects the normal function of the substation.The intelligent operation of the transformer mainly involves the protection and status monitoring of the transformer, so as to achieve real-time monitoring of the transformer and ultimately ensure the safety and reliability of power supply.
Insulation level: There are standards for insulation levels. The insulation level of a transformer with a rated high voltage of 35 kV and a rated low voltage of 10 kV is represented as LI200AC85/LI75AC35, where LI200 indicates that the transformer has a high-voltage lightning impulse withstand voltage of 200 kV, a power frequency withstand voltage of 85 kV, and a low-voltage lightning impulse withstand voltage of 75 kV, and a power frequency withstand voltage of 35 kV. The current insulation level of Aux High-Tech Co., Ltd.’s oil-immersed transformer products is LI75AC35, indicating that the transformer has a high-voltage lightning impulse withstand voltage of 75 kV and a power frequency withstand voltage of 35 kV. Because the low voltage is 400 V, it can be ignored.
When is it not allowed to adjust the tap changer of the transformer on-load voltage regulating device? The on-load voltage regulating device is a common accessory equipment of the transformer, which is used to adjust the transformation ratio when the transformer is running, so as to achieve the purpose of adjusting the output voltage. When using the on-load pressure regulator, the following points need to be paid attention to: It is not allowed to operate under live conditions: because the transformer is working under live conditions, the tap changer of the on-load voltage regulating device will have an arc when it is adjusted, so it is not allowed to operate the tap changer under live conditions. Frequent adjustments are not allowed: frequent adjustments to the tap changer of the on-load tap changer may cause damage to the tap changer or poor contact, thereby affecting the normal operation of the transformer.
The cooling methods are divided into natural air cooling (AN) and forced air cooling (AF). When air cooled naturally, the transformer can run continuously for a long time under rated capacity. When forced air cooling, transformer output capacity can be increased by 50%. Suitable for intermittent overload operation, or emergency overload operation; Because the load loss and impedance voltage increase greatly during overload, it is in non-economic operation state, so it should not be in continuous overload operation for a long time.Welcome to inquiry price for dry type substation transformer.